Safety Technology International, Inc.
2
306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Fax: 248-673-1246
Toll Free: 800-888-4784 E-mail: info@sti-usa.com
Web: www.sti-usa.com
Safety Technology International (Europe) Ltd.
U
nit 49G Pipers Road • Park Farm Industrial Estate • Redditch
W
orcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 Freephone: 0800 085 1678 (UK only)
E-mail: [email protected] • Web: www.sti-europe.com
5. Mount the heater plate assembly to the back box with
control thermostat toward bottom of enclosure (see
Illustration 2). Be sure to route wires for electronic device
through the hole in the center of the heater plate before
attaching heater plate. For vertical mounting (hinges to
right or left side) be sure control thermostat is towards
the bottom of the enclosure.
6. Connect the electronic device and mount to the heater
plate in mounting holes indicated using #6 - 32 x 1/2”
screws (2) provided.
NOTE: If moisture buildup occurs, drill a weep
hole on bottom side of back box.
4. Connect heater power and control wires.
a. Connect low temperature monitor terminals to supervisory panel
if used (see Illustration 3).
b. Connect power terminals to power source. 12-24 volt AC/DC.
Heating capacity is determined by input voltage. Be sure
the power source has enough capacity to support the load
at the input voltage.
12 Volt, 19 WATTS
16.5 Volt, 36 WATTS
24 Volt, 77 WATTS
• 16.5 VAC adapter included
“HEAT ON”
RED LED
“POWER ON”
GREEN LED
CONTROL THERMOSTAT
CLOSED @ 50°F
OPEN @ 70°F
#6-32 THREADED HOLES
FOR MOUNTING ELECTRONIC
DEVICE (6 PLACES)
SUB-7520-HTR
(FRONT VIEW)
D
EVICE WIRING
ACCESS HOLE
JAN2010
7520HTR INSTALL